comparison gcc/testsuite/ada/acats/tests/ce/ce3806h.ada @ 111:04ced10e8804

gcc 7
author kono
date Fri, 27 Oct 2017 22:46:09 +0900
parents
children
comparison
equal deleted inserted replaced
68:561a7518be6b 111:04ced10e8804
1 -- CE3806H.ADA
2
3 -- Grant of Unlimited Rights
4 --
5 -- Under contracts F33600-87-D-0337, F33600-84-D-0280, MDA903-79-C-0687,
6 -- F08630-91-C-0015, and DCA100-97-D-0025, the U.S. Government obtained
7 -- unlimited rights in the software and documentation contained herein.
8 -- Unlimited rights are defined in DFAR 252.227-7013(a)(19). By making
9 -- this public release, the Government intends to confer upon all
10 -- recipients unlimited rights equal to those held by the Government.
11 -- These rights include rights to use, duplicate, release or disclose the
12 -- released technical data and computer software in whole or in part, in
13 -- any manner and for any purpose whatsoever, and to have or permit others
14 -- to do so.
15 --
16 -- DISCLAIMER
17 --
18 -- ALL MATERIALS OR INFORMATION HEREIN RELEASED, MADE AVAILABLE OR
19 -- DISCLOSED ARE AS IS. THE GOVERNMENT MAKES NO EXPRESS OR IMPLIED
20 -- WARRANTY AS TO ANY MATTER WHATSOEVER, INCLUDING THE CONDITIONS OF THE
21 -- SOFTWARE, DOCUMENTATION OR OTHER INFORMATION RELEASED, MADE AVAILABLE
22 -- OR DISCLOSED, OR THE OWNERSHIP, MERCHANTABILITY, OR FITNESS FOR A
23 -- PARTICULAR PURPOSE OF SAID MATERIAL.
24 --*
25 -- OBJECTIVE:
26 -- CHECK THAT FIXED_IO PUT RAISES LAYOUT_ERROR WHEN THE NUMBER OF
27 -- CHARACTERS TO BE OUTPUT EXCEEDS THE MAXIMUM LINE LENGTH. CHECK
28 -- THAT IT IS NOT RAISED, BUT RATHER NEW_LINE IS CALLED, WHEN THE
29 -- NUMBER DOES NOT EXCEED THE MAX, BUT WHEN ADDED TO THE CURRENT
30 -- COLUMN NUMBER, THE TOTAL EXCEEDS THE MAX.
31
32 -- APPLICABILITY CRITERIA:
33 -- THIS TEST IS APPLICABLE ONLY TO IMPLEMENTATIONS WHICH SUPPORT
34 -- TEXT FILES.
35
36 -- HISTORY:
37 -- JLH 09/15/87 CREATED ORIGINAL TEST.
38
39 WITH REPORT; USE REPORT;
40 WITH TEXT_IO; USE TEXT_IO;
41 WITH CHECK_FILE;
42
43 PROCEDURE CE3806H IS
44
45 BEGIN
46
47 TEST ("CE3806H", "CHECK THAT FIXED_IO PUT RAISES " &
48 "LAYOUT_ERROR CORRECTLY");
49
50 DECLARE
51 FT : FILE_TYPE;
52 TYPE FX IS DELTA 0.01 RANGE -200.0 .. 200.0;
53 PACKAGE FXIO IS NEW FIXED_IO (FX);
54 USE FXIO;
55 INCOMPLETE : EXCEPTION;
56 X : FX := 126.5;
57 Y : FX := -134.0;
58 Z : FX := 120.0;
59
60 BEGIN
61
62 BEGIN
63 CREATE (FT, OUT_FILE, LEGAL_FILE_NAME);
64 EXCEPTION
65 WHEN USE_ERROR =>
66 NOT_APPLICABLE ("USE_ERROR RAISED ON TEXT CREATE " &
67 "WITH OUT_FILE MODE");
68 RAISE INCOMPLETE;
69 WHEN NAME_ERROR =>
70 NOT_APPLICABLE ("NAME_ERROR RAISED ON TEXT " &
71 "CREATE WITH OUT_FILE MODE");
72 RAISE INCOMPLETE;
73 END;
74
75 SET_LINE_LENGTH (FT, 4);
76
77 BEGIN
78 PUT (FT, X, FORE => 3, AFT => 1);
79 FAILED ("LAYOUT_ERROR NOT RAISED - FIXED");
80 EXCEPTION
81 WHEN LAYOUT_ERROR =>
82 NULL;
83 WHEN OTHERS =>
84 FAILED ("WRONG EXCEPTION RAISED - FIXED");
85 END;
86
87 SET_LINE_LENGTH (FT,7);
88
89 BEGIN
90 PUT (FT, Y, FORE => 3, AFT => 2);
91 EXCEPTION
92 WHEN LAYOUT_ERROR =>
93 FAILED ("LAYOUT_ERROR RAISED SECOND PUT - " &
94 "FIXED");
95 WHEN OTHERS =>
96 FAILED ("SOME EXCEPTION RAISED SECOND PUT - " &
97 "FIXED");
98 END;
99
100 BEGIN
101 PUT (FT,Z, FORE => 4, AFT => 2);
102 IF LINE (FT) /= 2 THEN
103 FAILED ("NEW_LINE NOT CALLED - FIXED");
104 END IF;
105 EXCEPTION
106 WHEN LAYOUT_ERROR =>
107 FAILED ("LAYOUT_ERROR RAISED THIRD PUT - " &
108 "FIXED");
109 WHEN OTHERS =>
110 FAILED ("EXCEPTION RAISED THIRD PUT - FIXED");
111 END;
112
113 BEGIN
114 PUT (FT, "Y");
115 PUT (FT, Z, FORE => 3, AFT => 0);
116 NEW_LINE (FT);
117 PUT (FT, "Z");
118 PUT (FT, Y, FORE => 3, AFT => 2);
119 EXCEPTION
120 WHEN LAYOUT_ERROR =>
121 FAILED ("LAYOUT_ERROR RAISED LAST PUT - " &
122 "FIXED");
123 WHEN OTHERS =>
124 FAILED ("EXCEPTION RAISED LAST PUT - FIXED ");
125 END;
126
127 CHECK_FILE (FT, "-134.00# 120.00#Y120.0#Z#-134.00#@%");
128
129 BEGIN
130 DELETE (FT);
131 EXCEPTION
132 WHEN USE_ERROR =>
133 NULL;
134 END;
135
136 EXCEPTION
137 WHEN INCOMPLETE =>
138 NULL;
139
140 END;
141
142 RESULT;
143
144 END CE3806H;