diff gcc/testsuite/ada/acats/tests/cc/cc1221d.ada @ 111:04ced10e8804

gcc 7
author kono
date Fri, 27 Oct 2017 22:46:09 +0900
parents
children
line wrap: on
line diff
--- /dev/null	Thu Jan 01 00:00:00 1970 +0000
+++ b/gcc/testsuite/ada/acats/tests/cc/cc1221d.ada	Fri Oct 27 22:46:09 2017 +0900
@@ -0,0 +1,173 @@
+-- CC1221D.ADA
+
+--                             Grant of Unlimited Rights
+--
+--     Under contracts F33600-87-D-0337, F33600-84-D-0280, MDA903-79-C-0687,
+--     F08630-91-C-0015, and DCA100-97-D-0025, the U.S. Government obtained 
+--     unlimited rights in the software and documentation contained herein.
+--     Unlimited rights are defined in DFAR 252.227-7013(a)(19).  By making 
+--     this public release, the Government intends to confer upon all 
+--     recipients unlimited rights  equal to those held by the Government.  
+--     These rights include rights to use, duplicate, release or disclose the 
+--     released technical data and computer software in whole or in part, in 
+--     any manner and for any purpose whatsoever, and to have or permit others 
+--     to do so.
+--
+--                                    DISCLAIMER
+--
+--     ALL MATERIALS OR INFORMATION HEREIN RELEASED, MADE AVAILABLE OR
+--     DISCLOSED ARE AS IS.  THE GOVERNMENT MAKES NO EXPRESS OR IMPLIED 
+--     WARRANTY AS TO ANY MATTER WHATSOEVER, INCLUDING THE CONDITIONS OF THE
+--     SOFTWARE, DOCUMENTATION OR OTHER INFORMATION RELEASED, MADE AVAILABLE 
+--     OR DISCLOSED, OR THE OWNERSHIP, MERCHANTABILITY, OR FITNESS FOR A
+--     PARTICULAR PURPOSE OF SAID MATERIAL.
+--*
+-- OBJECTIVE:
+--     FOR A FORMAL INTEGER TYPE, CHECK THAT THE FOLLOWING BASIC
+--     OPERATIONS ARE IMPLICITLY DECLARED AND ARE THEREFORE AVAILABLE
+--     WITHIN THE GENERIC UNIT:  EXPLICIT CONVERSION TO AND FROM REAL
+--     TYPES AND IMPLICIT CONVERSION FROM INTEGER LITERALS.
+
+-- HISTORY:
+--     BCB 11/12/87  CREATED ORIGINAL TEST FROM SPLIT OF CC1221A.ADA
+
+WITH SYSTEM; USE SYSTEM;
+WITH REPORT; USE REPORT;
+PROCEDURE CC1221D IS
+
+     SUBTYPE SUBINT IS INTEGER RANGE -100 .. 100;
+     TYPE INT IS RANGE -300 .. 300;
+     SUBTYPE SINT1 IS INT
+          RANGE INT (IDENT_INT (-4)) .. INT (IDENT_INT (4));
+     TYPE INT1 IS RANGE -6 .. 6;
+
+BEGIN
+     TEST ( "CC1221D", "FOR A FORMAL INTEGER TYPE, CHECK THAT THE " &
+                       "FOLLOWING BASIC OPERATIONS ARE IMPLICITLY " &
+                       "DECLARED AND ARE THEREFORE AVAILABLE " &
+                       "WITHIN THE GENERIC UNIT:  EXPLICIT " &
+                       "CONVERSION TO AND FROM REAL TYPES AND " &
+                       "IMPLICIT CONVERSION FROM INTEGER LITERALS");
+
+     DECLARE -- (D) CHECKS FOR EXPLICIT CONVERSION TO AND FROM OTHER
+             --     NUMERIC TYPES, AND IMPLICIT CONVERSION FROM
+             --     INTEGER LITERALS.
+
+          GENERIC
+               TYPE T IS RANGE <>;
+          PROCEDURE P (STR : STRING);
+
+          PROCEDURE P (STR : STRING) IS
+
+               TYPE FIXED IS DELTA 0.1 RANGE -100.0 .. 100.0;
+               FI0  : FIXED := 0.0;
+               FI2  : FIXED := 2.0;
+               FIN2 : FIXED := -2.0;
+
+               FL0  : FLOAT := 0.0;
+               FL2  : FLOAT := 2.0;
+               FLN2 : FLOAT := -2.0;
+
+               T0  : T := 0;
+               T2  : T := 2;
+               TN2 : T := -2;
+
+               FUNCTION IDENT (X : T) RETURN T IS
+               BEGIN
+                    IF EQUAL (3, 3) THEN
+                         RETURN X;
+                    ELSE
+                         RETURN T'FIRST;
+                    END IF;
+               END IDENT;
+
+          BEGIN
+               IF T0 + 1 /= 1 THEN
+                    FAILED ( "INCORRECT RESULTS FOR IMPLICIT " &
+                             "CONVERSION WITH TYPE " & STR & " - 1" );
+               END IF;
+
+               IF T2 + 1 /= 3 THEN
+                    FAILED ( "INCORRECT RESULTS FOR IMPLICIT " &
+                             "CONVERSION WITH TYPE " & STR & " - 2" );
+               END IF;
+
+               IF TN2 + 1 /= -1 THEN
+                    FAILED ( "INCORRECT RESULTS FOR IMPLICIT " &
+                             "CONVERSION WITH TYPE " & STR & " - 3" );
+               END IF;
+
+               IF T (FI0) /= T0 THEN
+                    FAILED ( "INCORRECT CONVERSION FROM " &
+                             "FIXED VALUE 0.0 WITH TYPE " & STR);
+               END IF;
+
+               IF T (FI2) /= IDENT (T2) THEN
+                    FAILED ( "INCORRECT CONVERSION FROM " &
+                             "FIXED VALUE 2.0 WITH TYPE " & STR);
+               END IF;
+
+               IF T (FIN2) /= TN2 THEN
+                    FAILED ( "INCORRECT CONVERSION FROM " &
+                             "FIXED VALUE -2.0 WITH TYPE " & STR);
+               END IF;
+
+               IF T (FL0) /= IDENT (T0) THEN
+                    FAILED ( "INCORRECT CONVERSION FROM " &
+                             "FLOAT VALUE 0.0 WITH TYPE " & STR);
+               END IF;
+
+               IF T (FL2) /= T2 THEN
+                    FAILED ( "INCORRECT CONVERSION FROM " &
+                             "FLOAT VALUE 2.0 WITH TYPE " & STR);
+               END IF;
+
+               IF T (FLN2) /= IDENT (TN2) THEN
+                    FAILED ( "INCORRECT CONVERSION FROM " &
+                             "FLOAT VALUE -2.0 WITH TYPE " & STR);
+               END IF;
+
+               IF FIXED (T0) /= FI0 THEN
+                    FAILED ( "INCORRECT CONVERSION TO " &
+                             "FIXED VALUE 0.0 WITH TYPE " & STR);
+               END IF;
+
+               IF FIXED (IDENT (T2)) /= FI2 THEN
+                    FAILED ( "INCORRECT CONVERSION TO " &
+                             "FIXED VALUE 2.0 WITH TYPE " & STR);
+               END IF;
+
+               IF FIXED (TN2) /= FIN2 THEN
+                    FAILED ( "INCORRECT CONVERSION TO " &
+                             "FIXED VALUE -2.0 WITH TYPE " & STR);
+               END IF;
+
+               IF FLOAT (IDENT (T0)) /= FL0 THEN
+                    FAILED ( "INCORRECT CONVERSION TO " &
+                             "FLOAT VALUE 0.0 WITH TYPE " & STR);
+               END IF;
+
+               IF FLOAT (T2) /= FL2 THEN
+                    FAILED ( "INCORRECT CONVERSION TO " &
+                             "FLOAT VALUE 2.0 WITH TYPE " & STR);
+               END IF;
+
+               IF FLOAT (IDENT (TN2)) /= FLN2 THEN
+                    FAILED ( "INCORRECT CONVERSION TO " &
+                             "FLOAT VALUE -2.0 WITH TYPE " & STR);
+               END IF;
+
+          END P;
+
+          PROCEDURE P1 IS NEW P (SUBINT);
+          PROCEDURE P2 IS NEW P (SINT1);
+          PROCEDURE P3 IS NEW P (INT1);
+
+     BEGIN
+           P1 ( "SUBINT" );
+           P2 ( "SINT" );
+           P3 ( "INT1" );
+     END; -- (D).
+
+     RESULT;
+END CC1221D;