view examples_forth/asm6309.4 @ 175:c83545730d6c

openm
author Shinji KONO <kono@ie.u-ryukyu.ac.jp>
date Sun, 14 Apr 2019 17:17:34 +0900
parents 2088fd998865
children
line wrap: on
line source

\ 6309 assembler

BASE @ HEX

: DEFER CREATE 0 , DOES> @ EXECUTE ;
: IS ' >BODY ! ;

VOCABULARY ASSEMBLER
ASSEMBLER ALSO DEFINITIONS

' C! DEFER VC! IS VC! \ Vectorize the important words so we can cross
' C@ DEFER VC@ IS VC@ \ assemble and self-assemble using the same code.
' !  DEFER V!  IS V!
' @  DEFER V@  IS V@
' C, DEFER C, IS C,
' ,  DEFER ,  IS ,
' HERE DEFER HERE IS HERE
' ALLOT DEFER ALLOT IS ALLOT

VARIABLE VDP
: VHERE ( --- addr)
  VDP @ ;
: VALLOT VDP +! ;
: VC, ( c --- )
  VHERE VC! 1 VALLOT ;
: V, ( n ---)
  VHERE V! 2 VALLOT ;
: ORG VDP ! ;

: <MARK ( --- addr )
  HERE ;
: <RESOLVE ( addr ---)
  HERE 1+ - C, ;
: >MARK ( --- addr )
  HERE 0 C, ;
: >RESOLVE ( addr --- )
  HERE OVER 1+ - SWAP VC! ;

VARIABLE ?MEMIMM                   \ Memory + immediate (AIM, OIM, EOIM)
VARIABLE ?OPCODE  VARIABLE OPCODE  \ Opcode byte
VARIABLE ?POSTBYTE VARIABLE POSTBYTE \ Byte after opcode indicating mode.
VARIABLE ?OPERAND  \ Address or data after instruction.
VARIABLE MODE \ True is direct addressing false is other.
VARIABLE DPAGE \ Direct page address.
: SETDP ( n ---) \ Set direct page.
  100 * DPAGE ! ;
0 SETDP

: NOINSTR \ Reset all the instruction flags so there will be no instruction.
  ?OPCODE OFF ?POSTBYTE OFF ?OPERAND OFF MODE OFF ?MEMIMM OFF ;
: A; \ Assemble current instruction and reset instruction flags.
  MODE @  IF \ direct addresiing?
   DUP DPAGE @ - 0FF U> IF \ Is address 16 bits?
    2 ?OPERAND ! \ Indicate 16 bits address.
    OPCODE @ 0F0 AND 0= \ Change opcode byte.
     IF 70 OPCODE +!
     ELSE 20 OPCODE +!
     THEN
   ELSE 1 ?OPERAND ! \ Indicate 8 bis address.
   THEN
  THEN
  ?OPCODE @ IF
     OPCODE @ DUP 100 > IF
       DUP 8 RSHIFT C,  \ assemble prebyte  
     THEN
     C,
  THEN
  ?MEMIMM @ IF
      ?OPERAND @ IF SWAP THEN \ move immediate byte from under operand.
      C,
  THEN
  ?POSTBYTE @ IF POSTBYTE @ C, THEN
  ?OPERAND @ IF
   CASE ?OPERAND @
    1 OF C, ENDOF            \ 8 bits data/address.
    2 OF , ENDOF             \ 16 bits data/address.
    3 OF HERE 1+ - C, ENDOF  \ 8 bits relative address.
    4 OF HERE 2 + - , ENDOF  \ 16 bits relative address.
    5 OF , , ENDOF           \ 32 bits immediate (LDQ)
    6 OF                     \ single-bit operations.
     >R                      \ Save DP address.
     SWAP 3 LSHIFT OR        \ or the bit numbers together.
     SWAP 6 AND 5 LSHIFT OR  \ Add register number.
     C,                      \ Store post-byte (reg-srcbit-dstbit)
     R> C,                   \ Store direct address.
     ENDOF              \ LDBT etc.
   ENDCASE
  THEN NOINSTR ;


: LABEL A; HERE CONSTANT ;


HEX

: # \ Signal immediate mode.
   MODE OFF -10 OPCODE +!
   ?OPERAND @ 5 = IF \ Special case is LDQ immediate.
     0CD OPCODE !
   THEN
;

: USE-POSTBYTE \ Signal that postbyte must be used.
  MODE OFF
  ?POSTBYTE ON
  OPCODE @ 0F0 AND 0= IF
   60 OPCODE +!
  ELSE
   OPCODE @ 80 AND IF
    10 OPCODE +!
   THEN
  THEN ;

: [] \ Signal indirect mode.
  MODE @ IF \ Indirect addressing with 16-bits addres, no postbyte made yet.
   USE-POSTBYTE
   9F POSTBYTE !   \ Make postbyte.
   2 ?OPERAND !     \ Indicate 16-bits address.
  ELSE
   POSTBYTE @ 80 AND 0= IF \ 5-bits address format already assembled?
    POSTBYTE @ 1F AND DUP 10 AND 0<> 0E0 AND OR
    1 ?OPERAND !            \ Signal operand.
    POSTBYTE @ 60 AND 98 OR POSTBYTE ! \ Change postbyte.
   ELSE
    POSTBYTE @ 9F AND 8F =
    IF
      POSTBYTE @ 1+ POSTBYTE ! \ special case for ,W indexing
    ELSE
      POSTBYTE @ 10 OR POSTBYTE ! \ Indicate indirect addressing.
    THEN
   THEN
  THEN ;

: ,R \ Modes with a constant offset from a register.
  CREATE C,
  DOES> USE-POSTBYTE
        C@ POSTBYTE ! \ Make register field in postbyte.
        DUP 0= IF
         84 POSTBYTE +! DROP \ Zero offset.
         ?OPERAND OFF
        ELSE
         DUP -10 >= OVER 0F <= AND IF \ 5-bit offset.
          1F AND POSTBYTE +!
          ?OPERAND OFF
         ELSE
          DUP 80 + 100 U< IF \ 8-bit offset.
           88 POSTBYTE +!
           1 ?OPERAND !
          ELSE
           89 POSTBYTE +!    \ 16-bit offset.
           2 ?OPERAND !
          THEN
         THEN
        THEN ;
00 ,R ,X
20 ,R ,Y
40 ,R ,U
60 ,R ,S

: ,W \ Addressing with constant offset from W register.
  USE-POSTBYTE
  DUP 0= IF
    8F POSTBYTE ! DROP  \ offset = 0
    ?OPERAND OFF
  ELSE
    0AF POSTBYTE !   \ 16-bit offset
    2 ?OPERAND !
  THEN
;

: AMODE \ addressing modes with no operands.
  CREATE C,
  DOES> USE-POSTBYTE
        C@ POSTBYTE !
        ?OPERAND OFF ;
080 AMODE ,X+   081 AMODE ,X++ 082 AMODE ,-X   083 AMODE ,--X
085 AMODE B,X   086 AMODE A,X  08B AMODE D,X
087 AMODE E,X   08A AMODE F,X  08E AMODE W,X
0A0 AMODE ,Y+   0A1 AMODE ,Y++ 0A2 AMODE ,-Y   0A3 AMODE ,--Y
0A5 AMODE B,Y   0A6 AMODE A,Y  0AB AMODE D,Y
0A7 AMODE E,Y   0AA AMODE F,Y  0AE AMODE W,Y
0C0 AMODE ,U+   0C1 AMODE ,U++ 0C2 AMODE ,-U   0C3 AMODE ,--U
0C5 AMODE B,U   0C6 AMODE A,U  0CB AMODE D,U
0C7 AMODE E,U   0CA AMODE F,U  0CE AMODE W,U
0E0 AMODE ,S+   0E1 AMODE ,S++ 0E2 AMODE ,-S   0E3 AMODE ,--S
0E5 AMODE B,S   0E6 AMODE A,S  0EB AMODE D,S
0E7 AMODE E,S   0EA AMODE F,S  0EE AMODE W,S
0CF AMODE ,W++  0EF AMODE ,--W

: ,PCR \ Signal program counter relative.
  USE-POSTBYTE
  DUP
  HERE OPCODE @ 0FF U> - 3 + - \ Subtract address after instruction
  80 + 100 U< IF \ 8-bits offset good?
   3 ?OPERAND !
   8C POSTBYTE !
  ELSE
   4 ?OPERAND !
   8D POSTBYTE !
  THEN ;

: USE-OPCODE ( w ---)
  ?OPCODE ON
  OPCODE ! ;

: GET-OPCODE ( addr -- )\
  >R A; R> @ USE-OPCODE ;

: IN1 \ Simple instructions with only opcode, possibly prebyte
  CREATE ,
  DOES> GET-OPCODE ;
12 IN1 NOP    13 IN1 SYNC
14 IN1 SEXW
19 IN1 DAA    1D IN1 SEX
39 IN1 RTS    3A IN1 ABX
3B IN1 RTI    3D IN1 MUL
1038 IN1 PSHSW 1039 IN1 PULSW
103A IN1 PSHUW 103B IN1 PULUW
3F IN1 SWI    103F IN1 SWI2 113F IN1 SWI3
40 IN1 NEGA   50 IN1 NEGB
43 IN1 COMA   53 IN1 COMB
44 IN1 LSRA   54 IN1 LSRB
46 IN1 RORA   56 IN1 RORB
47 IN1 ASRA   57 IN1 ASRB
48 IN1 ASLA   58 IN1 ASLB
48 IN1 LSLA   58 IN1 LSLB
49 IN1 ROLA   59 IN1 ROLB
4A IN1 DECA   5A IN1 DECB
4C IN1 INCA   5C IN1 INCB
4D IN1 TSTA   5D IN1 TSTB
4F IN1 CLRA   5F IN1 CLRB
1040 IN1 NEGD 1050 IN1 NEGW
1043 IN1 COMD 1051 IN1 COMW
1044 IN1 LSRD 1054 IN1 LSRW
1046 IN1 RORD 1056 IN1 RORW
1047 IN1 ASRD  \ what were they smoking when they decided to leave out ASRW/ASLW
1048 IN1 ASLD
1048 IN1 LSRD
1049 IN1 ROLD 1059 IN1 ROLW
104A IN1 DECD 105A IN1 DECW
104C IN1 INCD 105C IN1 INCW
104D IN1 TSTD 105D IN1 TSTW
104F IN1 CLRD 105F IN1 CLRW
1143 IN1 COME 1153 IN1 COMF
114A IN1 DECE 115A IN1 DECF
114C IN1 INCE 115C IN1 INCF
114D IN1 TSTE 115D IN1 TSTF
114F IN1 CLRE 115F IN1 CLRF

\ Though not no-operand instructions the LEA instructions
\ are treated correctly as the postbyte is added by the mode words.
30 IN1 LEAX   31 IN1 LEAY
32 IN1 LEAS   33 IN1 LEAU

: BR-8 \ relative branches with 8-bit offset
  CREATE ,
  DOES> GET-OPCODE 3 ?OPERAND ! ;
  20 BR-8 BRA   21 BR-8 BRN
  22 BR-8 BHI   23 BR-8 BLS
  24 BR-8 BCC   25 BR-8 BCS
  24 BR-8 BHS   25 BR-8 BLO
  26 BR-8 BNE   27 BR-8 BEQ
  28 BR-8 BVC   29 BR-8 BVS
  2A BR-8 BPL   2B BR-8 BMI
  2C BR-8 BGE   2D BR-8 BLT
  2E BR-8 BGT   2F BR-8 BLE
  8D BR-8 BSR

: LBRA
  A; 16 USE-OPCODE 4 ?OPERAND ! ;
: LBSR
  A; 17 USE-OPCODE 4 ?OPERAND ! ;

: BR16 \ Relative branches with 16-bit offset.
  CREATE ,
  DOES> GET-OPCODE 4 ?OPERAND ! ;
                  1021 BR16 LBRN
  1022 BR16 LBHI  1023 BR16 LBLS
  1024 BR16 LBCC  1025 BR16 LBCS
  1024 BR16 LBHS  1025 BR16 LBLO
  1026 BR16 LBNE  1027 BR16 LBEQ
  1028 BR16 LBVC  1029 BR16 LBVS
  102A BR16 LBPL  102B BR16 LBMI
  102C BR16 LBGE  102D BR16 LBLT
  102E BR16 LBGT  102F BR16 LBLE

: IN2 \ Instructions with one immediate data byte.
  CREATE ,
  DOES> GET-OPCODE 1 ?OPERAND ! ;
1A IN2 ORCC  1C IN2 ANDCC  3C IN2 CWAI
113C IN2 BITMD 113D IN2 LDMD 
: % ( --- n) \ Interpret next word as a binary number.
  BASE @ 2 BASE ! BL WORD NUMBER? drop DROP SWAP BASE ! ;

: REG \ Registers as used in PUSH PULL TFR and EXG instructions.
  CREATE C, C,
  DOES> ?OPERAND @ IF \ Is a PUSH/PULL instruction meant?
         1+ C@ OR
        ELSE
         C@ POSTBYTE +! \ It's a TFR,EXG instruction.
        THEN ;
06 00 REG D,  06 00 REG D
10 10 REG X,  10 01 REG X
20 20 REG Y,  20 02 REG Y
40 30 REG U,  40 03 REG U
40 40 REG S,  40 04 REG S
80 50 REG PC, 80 05 REG PC
00 60 REG W,  00 06 REG W
00 70 REG V,  00 07 REG V
02 80 REG A,  02 08 REG A
04 90 REG B,  04 09 REG B
01 A0 REG CC, 01 0A REG CC
08 B0 REG DP, 08 0B REG DP
00 C0 REG Z,  08 0C REG Z \ Zero register.
00 E0 REG E,  00 0E REG E
00 F0 REG F,  00 0F REG F

: R2R \ Reg to reg instructions
  CREATE , DOES> GET-OPCODE ?POSTBYTE ON 0 POSTBYTE ! ;
  1E R2R EXG
  1F R2R TFR
1030 R2R ADDR
1031 R2R ADCR
1032 R2R SUBR
1033 R2R SBCR
1034 R2R ANDR
1035 R2R ORR
1036 R2R EORR
1037 R2R CMPR

1138 R2R TFM++ \ TFM++ X, Y   for tfm x+,y+
1139 R2R TFM-- \ TFM-- X, Y   for tfm x-,y-
113A R2R TFM+0 \ TFM+0 X, Y   for tfm x+,y
113B R2R TFM0+ \ TFM0+ X, Y   for tfm x,y+


: STK \ Stack instructions.
  CREATE ,
  DOES> GET-OPCODE
        1 ?OPERAND ! 0 ;
34 STK PSHS  35 STK PULS
36 STK PSHU  37 STK PULU

: OP-8 \ Instructions with 8-bits data.
  CREATE ,
  DOES> GET-OPCODE
        MODE ON
        1 ?OPERAND ! ;
00 OP-8 NEG  03 OP-8 COM
04 OP-8 LSR  06 OP-8 ROR
07 OP-8 ASR  08 OP-8 ASL
08 OP-8 LSL  09 OP-8 ROL
0A OP-8 DEC  0C OP-8 INC
0D OP-8 TST  0E OP-8 JMP
0F OP-8 CLR
90 OP-8 SUBA 0D0 OP-8 SUBB
91 OP-8 CMPA 0D1 OP-8 CMPB
92 OP-8 SBCA 0D2 OP-8 SBCB
94 OP-8 ANDA 0D4 OP-8 ANDB
95 OP-8 BITA 0D5 OP-8 BITB
96 OP-8 LDA  0D6 OP-8 LDB
97 OP-8 STA  0D7 OP-8 STB
98 OP-8 EORA 0D8 OP-8 EORB
99 OP-8 ADCA 0D9 OP-8 ADCB
9A OP-8 ORA  0DA OP-8 ORB
9B OP-8 ADDA 0DB OP-8 ADDB
9D OP-8 JSR
1190 OP-8 SUBE 11D0 OP-8 SUBF
1191 OP-8 CMPE 11D1 OP-8 CMPF
1196 OP-8 LDE  11D6 OP-8 LDF
1197 OP-8 STE  11D7 OP-8 STF
119B OP-8 ADDE 11DB OP-8 ADDF
119D OP-8 DIVD

: OP16 \ Instructions with 16-bits daia.
  CREATE ,
  DOES> GET-OPCODE
        MODE ON
        2 ?OPERAND ! ;
93 OP16 SUBD  0D3 OP16 ADDD
9C OP16 CMPX  0DC OP16 LDD  0DD OP16 STD
9E OP16 LDX   0DE OP16 LDU
9F OP16 STX   0DF OP16 STU
1090 OP16 SUBW 1091 OP16 CMPW
1092 OP16 SBCD 1093 OP16 CMPD
1094 OP16 ANDD 1095 OP16 BITD
1096 OP16 LDW  1097 OP16 STW
1098 OP16 EORD 1099 OP16 ADCD
109A OP16 ORD  109B OP16 ADDW
109C OP16 CMPY
109E OP16 LDY  109F OP16 STY
10DE OP16 LDS  10DF OP16 STS
1193 OP16 CMPU 119C OP16 CMPS
119E OP16 DIVQ 119F OP16 MULD

: OP32 \ Instructions with 32-bits daia.
  CREATE ,
  DOES> GET-OPCODE
        MODE ON
        5 ?OPERAND ! ;
10DC OP32 LDQ 10DD OP32 STQ

: OP-MEMIMM \ Instructions with memory addressing and 8-bit immediate
  CREATE ,
  DOES> GET-OPCODE
        MODE ON ?MEMIMM ON
        1 ?OPERAND ! ;
01 OP-MEMIMM OIM
02 OP-MEMIMM AIM
05 OP-MEMIMM EIM
0B OP-MEMIMM TIM

: OP-BIT \ Instructions for single bit in A,B,CC register and direct page.
  CREATE ,
  DOES> GET-OPCODE
  6 ?OPERAND ! 0 ;
1130 OP-BIT BAND
1131 OP-BIT BIAND
1132 OP-BIT BOR
1133 OP-BIT BIOR
1134 OP-BIT BEOR
1135 OP-BIT BIEOR
1136 OP-BIT LDBT
1137 OP-BIT STBT

\ Structured assembler constructs.
: IF >R A; R> C, >MARK ;
: THEN A; >RESOLVE ;
: ELSE A; 20 C, >MARK SWAP >RESOLVE ;
: BEGIN A; <MARK ;
: UNTIL >R A; R> C, <RESOLVE ;
: WHILE >R A; R> C, >MARK ;
: REPEAT A; 20 C, SWAP <RESOLVE >RESOLVE ;
: AGAIN 20 UNTIL ;
22 CONSTANT U<= 23 CONSTANT U>
24 CONSTANT U<  25 CONSTANT U>=
26 CONSTANT 0=  27 CONSTANT 0<>
28 CONSTANT VS  29 CONSTANT VC
2A CONSTANT 0<  2B CONSTANT 0>=
2C CONSTANT <   2D CONSTANT >=
2E CONSTANT <=  2F CONSTANT >

: ENDASM \ End assembly.
  A; PREVIOUS ;
FORTH DEFINITIONS
: ASSEMBLE \ Start assembly.
  ALSO ASSEMBLER NOINSTR ;

: CODE CREATE -3 ALLOT ASSEMBLE ;
: END-CODE [ ASSEMBLER ] ENDASM [ FORTH ] ;

PREVIOUS FORTH DEFINITIONS

BASE ! \ Restore the original base.