diff gcc/testsuite/ada/acats/tests/c9/c974007.a @ 111:04ced10e8804

gcc 7
author kono
date Fri, 27 Oct 2017 22:46:09 +0900
parents
children
line wrap: on
line diff
--- /dev/null	Thu Jan 01 00:00:00 1970 +0000
+++ b/gcc/testsuite/ada/acats/tests/c9/c974007.a	Fri Oct 27 22:46:09 2017 +0900
@@ -0,0 +1,205 @@
+-- C974007.A
+--
+--                             Grant of Unlimited Rights
+--
+--     Under contracts F33600-87-D-0337, F33600-84-D-0280, MDA903-79-C-0687,
+--     F08630-91-C-0015, and DCA100-97-D-0025, the U.S. Government obtained 
+--     unlimited rights in the software and documentation contained herein.
+--     Unlimited rights are defined in DFAR 252.227-7013(a)(19).  By making 
+--     this public release, the Government intends to confer upon all 
+--     recipients unlimited rights  equal to those held by the Government.  
+--     These rights include rights to use, duplicate, release or disclose the 
+--     released technical data and computer software in whole or in part, in 
+--     any manner and for any purpose whatsoever, and to have or permit others 
+--     to do so.
+--
+--                                    DISCLAIMER
+--
+--     ALL MATERIALS OR INFORMATION HEREIN RELEASED, MADE AVAILABLE OR
+--     DISCLOSED ARE AS IS.  THE GOVERNMENT MAKES NO EXPRESS OR IMPLIED 
+--     WARRANTY AS TO ANY MATTER WHATSOEVER, INCLUDING THE CONDITIONS OF THE
+--     SOFTWARE, DOCUMENTATION OR OTHER INFORMATION RELEASED, MADE AVAILABLE 
+--     OR DISCLOSED, OR THE OWNERSHIP, MERCHANTABILITY, OR FITNESS FOR A
+--     PARTICULAR PURPOSE OF SAID MATERIAL.
+--*
+--
+-- OBJECTIVE:
+--      Check that the sequence of statements of the triggering alternative
+--      of an asynchronous select statement is not executed if the triggering
+--      statement is a protected entry call, and the entry is not accepted
+--      before the abortable part completes. Check that execution continues
+--      immediately following the asynchronous select.
+--
+-- TEST DESCRIPTION:
+--      Declare a main procedure containing an asynchronous select with a
+--      protected entry call as triggering statement. Declare a protected
+--      procedure which sets the protected entry's barrier true. Ensure
+--      that the entry call is never accepted by not calling the protected
+--      procedure; the barrier remains false, and the entry call from
+--      asynchronous select is queued. Since the abortable part will complete
+--      before the entry is accepted, the sequence of statements of the
+--      triggering alternative is never executed.
+--
+--
+-- CHANGE HISTORY:
+--      06 Dec 94   SAIC    ACVC 2.0
+--
+--!
+
+
+package C974007_0 is  -- Automated teller machine abstraction.
+
+
+   -- Flags for testing purposes:
+   -- 
+   Abortable_Part_Executed       : Boolean := False;
+   Perform_Transaction_Executed  : Boolean := False;
+   Triggering_Statement_Executed : Boolean := False;
+
+
+   type Key_Enum is (None, Cancel, Deposit, Withdraw);
+
+   type Card_Number_Type is private;
+   type Card_PIN_Type    is private;
+   type ATM_Card_Type    is private;
+
+
+   Transaction_Canceled : exception;
+
+
+   protected type ATM_Keyboard_Protected is
+      entry Cancel_Pressed;
+      procedure Read_Key;
+   private
+      Last_Key_Pressed : Key_Enum := None;
+   end ATM_Keyboard_Protected;
+
+
+   procedure Read_Card (Card : in out ATM_Card_Type);
+
+   procedure Validate_Card (Card : in ATM_Card_Type);
+
+   procedure Perform_Transaction (Card : in ATM_Card_Type);
+
+private
+
+   type Card_Number_Type is range   1 .. 9999;
+   type Card_PIN_Type    is range 100 ..  999;
+
+   type ATM_Card_Type is record
+      Number : Card_Number_Type;
+      PIN    : Card_PIN_Type;
+   end record;
+
+end C974007_0;
+
+
+     --==================================================================--
+
+
+with Report;
+package body C974007_0 is
+
+
+   protected body ATM_Keyboard_Protected is
+
+      -- Barrier is false for the live of the test
+      entry Cancel_Pressed when (Last_Key_Pressed = Cancel) is  
+      begin                                                     
+      Triggering_Statement_Executed  := true;   -- Test has failed
+      -- (Note: cannot call Report.Failed in the protected entry body]
+      end Cancel_Pressed;
+
+      procedure Read_Key is                                     -- Never
+      begin                                                     -- called.
+         -- Simulate a procedure which reads user keyboard input, and
+         -- which is called by some interrupt handler.
+         Last_Key_Pressed := Cancel;
+      end Read_Key;
+
+   end ATM_Keyboard_Protected;
+
+
+   procedure Read_Card (Card : in out ATM_Card_Type) is
+   begin
+      Card.Number := 9999;
+      Card.PIN    := 111;
+   end Read_Card;
+
+
+   procedure Validate_Card (Card : in ATM_Card_Type) is
+   begin
+      Abortable_Part_Executed := True;
+   end Validate_Card;
+
+
+   procedure Perform_Transaction (Card : in ATM_Card_Type) is
+   begin
+      Perform_Transaction_Executed := True;
+   end Perform_Transaction;
+
+
+end C974007_0;
+
+
+     --==================================================================--
+with Report;
+
+with C974007_0;  -- Automated teller machine abstraction.
+use  C974007_0;
+
+procedure C974007 is
+
+   Card_Data : ATM_Card_Type;
+
+begin
+
+   Report.Test ("C974007", "ATC: trigger is protected entry call" &
+                              " and abortable part completes first");
+
+   Read_Card (Card_Data);
+
+   declare
+      Keyboard : C974007_0.ATM_Keyboard_Protected;
+   begin
+
+      --                                    --
+      -- Asynchronous select is tested here --
+      --                                    --
+
+      select
+         Keyboard.Cancel_Pressed;        -- Barrier is never set true, so
+                                         -- entry call is queued and never
+                                         -- accepted.
+
+         raise Transaction_Canceled;     -- Should not be executed.
+      then abort
+         Validate_Card (Card_Data);      -- This call completes before
+                                         -- Keyboard.Cancel_Pressed can be
+                                         -- accepted.
+      end select;
+      Perform_Transaction (Card_Data);   -- Execution proceeds here after
+                                         -- Validate_Card completes.
+   exception
+      when Transaction_Canceled =>
+         Report.Failed ("Triggering alternative sequence of statements " &
+                        "executed");
+   end;
+   
+   
+   if Triggering_Statement_Executed  then
+      Report.Failed ("Triggering statement was executed");
+   end if;
+
+   if not Abortable_Part_Executed then
+      Report.Failed ("Abortable part not executed");
+   end if;
+
+   if not Perform_Transaction_Executed then
+      Report.Failed ("Statements following asynchronous select not " &
+                     "executed");
+   end if;
+
+   Report.Result;
+
+end C974007;