view gcc/testsuite/ada/acats/tests/c9/c974007.a @ 158:494b0b89df80 default tip

...
author Shinji KONO <kono@ie.u-ryukyu.ac.jp>
date Mon, 25 May 2020 18:13:55 +0900
parents 04ced10e8804
children
line wrap: on
line source

-- C974007.A
--
--                             Grant of Unlimited Rights
--
--     Under contracts F33600-87-D-0337, F33600-84-D-0280, MDA903-79-C-0687,
--     F08630-91-C-0015, and DCA100-97-D-0025, the U.S. Government obtained 
--     unlimited rights in the software and documentation contained herein.
--     Unlimited rights are defined in DFAR 252.227-7013(a)(19).  By making 
--     this public release, the Government intends to confer upon all 
--     recipients unlimited rights  equal to those held by the Government.  
--     These rights include rights to use, duplicate, release or disclose the 
--     released technical data and computer software in whole or in part, in 
--     any manner and for any purpose whatsoever, and to have or permit others 
--     to do so.
--
--                                    DISCLAIMER
--
--     ALL MATERIALS OR INFORMATION HEREIN RELEASED, MADE AVAILABLE OR
--     DISCLOSED ARE AS IS.  THE GOVERNMENT MAKES NO EXPRESS OR IMPLIED 
--     WARRANTY AS TO ANY MATTER WHATSOEVER, INCLUDING THE CONDITIONS OF THE
--     SOFTWARE, DOCUMENTATION OR OTHER INFORMATION RELEASED, MADE AVAILABLE 
--     OR DISCLOSED, OR THE OWNERSHIP, MERCHANTABILITY, OR FITNESS FOR A
--     PARTICULAR PURPOSE OF SAID MATERIAL.
--*
--
-- OBJECTIVE:
--      Check that the sequence of statements of the triggering alternative
--      of an asynchronous select statement is not executed if the triggering
--      statement is a protected entry call, and the entry is not accepted
--      before the abortable part completes. Check that execution continues
--      immediately following the asynchronous select.
--
-- TEST DESCRIPTION:
--      Declare a main procedure containing an asynchronous select with a
--      protected entry call as triggering statement. Declare a protected
--      procedure which sets the protected entry's barrier true. Ensure
--      that the entry call is never accepted by not calling the protected
--      procedure; the barrier remains false, and the entry call from
--      asynchronous select is queued. Since the abortable part will complete
--      before the entry is accepted, the sequence of statements of the
--      triggering alternative is never executed.
--
--
-- CHANGE HISTORY:
--      06 Dec 94   SAIC    ACVC 2.0
--
--!


package C974007_0 is  -- Automated teller machine abstraction.


   -- Flags for testing purposes:
   -- 
   Abortable_Part_Executed       : Boolean := False;
   Perform_Transaction_Executed  : Boolean := False;
   Triggering_Statement_Executed : Boolean := False;


   type Key_Enum is (None, Cancel, Deposit, Withdraw);

   type Card_Number_Type is private;
   type Card_PIN_Type    is private;
   type ATM_Card_Type    is private;


   Transaction_Canceled : exception;


   protected type ATM_Keyboard_Protected is
      entry Cancel_Pressed;
      procedure Read_Key;
   private
      Last_Key_Pressed : Key_Enum := None;
   end ATM_Keyboard_Protected;


   procedure Read_Card (Card : in out ATM_Card_Type);

   procedure Validate_Card (Card : in ATM_Card_Type);

   procedure Perform_Transaction (Card : in ATM_Card_Type);

private

   type Card_Number_Type is range   1 .. 9999;
   type Card_PIN_Type    is range 100 ..  999;

   type ATM_Card_Type is record
      Number : Card_Number_Type;
      PIN    : Card_PIN_Type;
   end record;

end C974007_0;


     --==================================================================--


with Report;
package body C974007_0 is


   protected body ATM_Keyboard_Protected is

      -- Barrier is false for the live of the test
      entry Cancel_Pressed when (Last_Key_Pressed = Cancel) is  
      begin                                                     
      Triggering_Statement_Executed  := true;   -- Test has failed
      -- (Note: cannot call Report.Failed in the protected entry body]
      end Cancel_Pressed;

      procedure Read_Key is                                     -- Never
      begin                                                     -- called.
         -- Simulate a procedure which reads user keyboard input, and
         -- which is called by some interrupt handler.
         Last_Key_Pressed := Cancel;
      end Read_Key;

   end ATM_Keyboard_Protected;


   procedure Read_Card (Card : in out ATM_Card_Type) is
   begin
      Card.Number := 9999;
      Card.PIN    := 111;
   end Read_Card;


   procedure Validate_Card (Card : in ATM_Card_Type) is
   begin
      Abortable_Part_Executed := True;
   end Validate_Card;


   procedure Perform_Transaction (Card : in ATM_Card_Type) is
   begin
      Perform_Transaction_Executed := True;
   end Perform_Transaction;


end C974007_0;


     --==================================================================--
with Report;

with C974007_0;  -- Automated teller machine abstraction.
use  C974007_0;

procedure C974007 is

   Card_Data : ATM_Card_Type;

begin

   Report.Test ("C974007", "ATC: trigger is protected entry call" &
                              " and abortable part completes first");

   Read_Card (Card_Data);

   declare
      Keyboard : C974007_0.ATM_Keyboard_Protected;
   begin

      --                                    --
      -- Asynchronous select is tested here --
      --                                    --

      select
         Keyboard.Cancel_Pressed;        -- Barrier is never set true, so
                                         -- entry call is queued and never
                                         -- accepted.

         raise Transaction_Canceled;     -- Should not be executed.
      then abort
         Validate_Card (Card_Data);      -- This call completes before
                                         -- Keyboard.Cancel_Pressed can be
                                         -- accepted.
      end select;
      Perform_Transaction (Card_Data);   -- Execution proceeds here after
                                         -- Validate_Card completes.
   exception
      when Transaction_Canceled =>
         Report.Failed ("Triggering alternative sequence of statements " &
                        "executed");
   end;
   
   
   if Triggering_Statement_Executed  then
      Report.Failed ("Triggering statement was executed");
   end if;

   if not Abortable_Part_Executed then
      Report.Failed ("Abortable part not executed");
   end if;

   if not Perform_Transaction_Executed then
      Report.Failed ("Statements following asynchronous select not " &
                     "executed");
   end if;

   Report.Result;

end C974007;